Dynamic stiffness
Installation thickness (mm) · Dynamic stiffness s′ (MN/m³)
Approximate values digitized from PDF · technical review pending.
Review site · Imported datasheets are drafts and have not yet been approved.
Technical datasheet
Minerally bound thermal insulation fill for increased loads.
Data
| Property | Symbol | Value | Unit |
|---|---|---|---|
| 90% fractile value of thermal conductivity (dry) | λ10 dry, 90/90 | 0.0550 | W/mK |
| Design value of thermal conductivity | λR | 0.057 | W/mK |
| Bulk density of EPS dry mortar | LD | 120 | kg/m³ |
| Density of fresh mortar | FMD | 160 | kg/m³ |
| Dry bulk density | DMD | 145 | kg/m³ |
| Compressive stress at 10% deformationFrom 50 mm | CS (10)80 | 87 | kPa |
| Compressive stress at 10% deformationFrom 80 mm | CS (10)80 | 100 | kPa |
| Dimensional stability under compressive load and temperature exposure | DLT (1)5 | ≤ 3 | % |
| Water vapour diffusion resistanceAt 3 cm | µ*d | ≤ 6 | m |
| Reaction to fire according to EUROCLASS[***] | — | B-S1 | — |
| Type and particle size group of EPS aggregate | — | 0 - 8 R | — |
| Water absorption by short-term partial immersion | — | ≤ 2.0 | kg/m³ |
| Water addition per m³ | — | 45 | L |
| Minimum installation thickness | — | 25 | mm |
| Compressibility under load (difference between dL and dF)At 5 kPa (500 kg/m²) | — | 0.3 | mm |
| Working timeOpen time, 20°/60 % RH | — | min. 40 | min |
| Processing temperature min/max | — | +5° / +35° | C |
| Walkable after[*] | — | 24 hours | — |
| Ready for covering after (CM measurement) | — | ≤ 15 | CM-% |
| At installation thickness up to 200 mm23°C /50 % RH[**] | — | Approx. 2 days | — |
| Equilibrium moisture content based on ÖNORM EN 12429 | — | 5.5 | M% |
| Impact sound reduction (according to EN ISO 717-2) | — | 25 | dB |



Revision 09.2024Review site · Imported datasheets are drafts and have not yet been approved.
Designation code: BEPS-WD 130 R-PS(0-8)R-LD120-FMD160_DMD145-MU6-CS(10/80)-CC(1,2/0,5/10)10-DLT(1)5
| 90% fractile value of thermal conductivity (dry) | λ10 dry, 90/90 | 0.0550 W/mK |
| Design value of thermal conductivity | λR | 0.057 W/mK |
| Bulk density of EPS dry mortar | LD | 120 kg/m³ |
| Density of fresh mortar | FMD | 160 kg/m³ |
| Dry bulk density | DMD | 145 kg/m³ |
| Compressive stress at 10% deformationFrom 50 mm | CS (10)80 | 87 kPa |
| Compressive stress at 10% deformationFrom 80 mm | CS (10)80 | 100 kPa |
| Dimensional stability under compressive load and temperature exposure | DLT (1)5 | ≤ 3 % |
| Water vapour diffusion resistanceAt 3 cm | µ*d | ≤ 6 m |
| Reaction to fire according to EUROCLASS | B-S1*** | |
| Type and particle size group of EPS aggregate | 0 - 8 R | |
| Water absorption by short-term partial immersion | ≤ 2.0 kg/m³ | |
| Water addition per m³ | 45 L | |
| Minimum installation thickness | 25 mm | |
| Compressibility under load (difference between dL and dF) | At 5 kPa (500 kg/m²) | 0.3 mm |
| Working time | Open time, 20°/60 % RH | min. 40 min |
| Processing temperature min/max | +5° / +35° C | |
| Walkable after | 24 hours* | |
| Ready for covering after (CM measurement) | ≤ 15 CM-% | |
| At installation thickness up to 200 mm | 23°C /50 % RH | Approx. 2 days** |
| Equilibrium moisture content based on ÖNORM EN 12429 | 5.5 M% | |
| Impact sound reduction (according to EN ISO 717-2) | 25 dB |

Installation thickness (mm) · Dynamic stiffness s′ (MN/m³)
Approximate values digitized from PDF · technical review pending.
Installation thickness (cm) · Live load (kN/m²)
Approximate values digitized from PDF · technical review pending.