ThermoWhite®

Review site · Imported datasheets are drafts and have not yet been approved.

Technical datasheet

WD 130 R

Minerally bound thermal insulation fill for increased loads.

Product

Designation code
BEPS-WD 130 R-PS(0-8)R-LD120-FMD160_DMD145-MU6-CS(10/80)-CC(1,2/0,5/10)10-DLT(1)5

Data

Technical values

PropertySymbolValueUnit
90% fractile value of thermal conductivity (dry)λ10 dry, 90/900.0550W/mK
Design value of thermal conductivityλR0.057W/mK
Bulk density of EPS dry mortarLD120kg/m³
Density of fresh mortarFMD160kg/m³
Dry bulk densityDMD145kg/m³
Compressive stress at 10% deformationFrom 50 mmCS (10)8087kPa
Compressive stress at 10% deformationFrom 80 mmCS (10)80100kPa
Dimensional stability under compressive load and temperature exposureDLT (1)5≤ 3%
Water vapour diffusion resistanceAt 3 cmµ*d≤ 6m
Reaction to fire according to EUROCLASS[***]—B-S1—
Type and particle size group of EPS aggregate—0 - 8 R—
Water absorption by short-term partial immersion—≤ 2.0kg/m³
Water addition per m³—45L
Minimum installation thickness—25mm
Compressibility under load (difference between dL and dF)At 5 kPa (500 kg/m²)—0.3mm
Working timeOpen time, 20°/60 % RH—min. 40min
Processing temperature min/max—+5° / +35°C
Walkable after[*]—24 hours—
Ready for covering after (CM measurement)—≤ 15CM-%
At installation thickness up to 200 mm23°C /50 % RH[**]—Approx. 2 days—
Equilibrium moisture content based on ÖNORM EN 12429—5.5M%
Impact sound reduction (according to EN ISO 717-2)—25dB

Dynamic stiffness

Installation thickness (mm) · Dynamic stiffness s′ (MN/m³)

Approximate values digitized from PDF · technical review pending.

14013012011010090807060504030201005060708090100110120130140150160170180190200Installation thickness (mm)Dynamic stiffness s′ (MN/m³)

Live load

Installation thickness (cm) · Live load (kN/m²)

Approximate values digitized from PDF · technical review pending.

222120191817161512345678910111213141516171819202122Installation thickness (cm)Live load (kN/m²)
Product certificates100 % HBCD-free
Product markingEPD Verified
CE markingCE marking wd130r

Footnotes

  1. *Depending on temperature and humidity.
  2. **The values are indicative. A CM measurement is required.
  3. ***In the event of a fire, EPS thermal insulation can prevent the spread of fire, but it does not constitute a fire barrier.