ThermoWhite®

Review site · Imported datasheets are drafts and have not yet been approved.

Technical datasheet

WD 150 R

Minerally bound levelling fill for increased loads

Product

Notice

Source review note: The original (03.2023) uses inconsistent footnote markers: *** for reaction to fire and ** for “approx. 2 days”, but only * and ** are explained. Source values reproduced unchanged; the footnote references require technical clarification.

Data

Technical values

PropertySymbolValueUnit
90% fractile value of thermal conductivity (dry)λ10 dry, 90/900.060W/mK
Bulk density of EPS dry mortarLD138kg/m³
Density of fresh mortarFMD200kg/m³
Dry bulk densityDMD180kg/m³
Compressive stress at 10 % deformationCS (10)120120kPa
Water vapour diffusion resistanceµ6—
Reaction to fire according to EUROCLASS[***]—E—
Type and particle size group of EPS aggregate—0 - 8 R—
Water addition per m³—55L
Live loadAt 10 cm—20kN/m²
Working timeOpen time, 20°/60 % RH—min. 40min
Processing temperature min/max—+5° / +35°C
Ready for covering after (CM measurement)—≤ 15CM-%
At installation thickness up to 200 mm23°C / 50 % RH[**]—approx. 2days
Product certificatesHBCD-free declaration from the original datasheet

Footnotes

  1. *Depending on temperature and relative humidity.
  2. **In the event of a fire, EPS thermal insulation can prevent the spread of fire, but it does not constitute a fire barrier.